Install

Installing and activating

  1. Run the installer

    Open the downloaded file and follow the steps. Windows will ask for administrator permission. It installs to Program Files, adds a Start menu shortcut and, if you choose, a desktop shortcut.

  2. If Windows SmartScreen appears

    The installer is digitally signed - Windows shows the publisher as Oliver Hayward, ONAC's founder. A new release can still show a blue "Windows protected your PC" message until it has built up a download history. Click More info, check the publisher is Oliver Hayward, then Run anyway.

  3. Buy a licence

    Pay securely through Stripe. Your licence key is shown on screen straight after payment - copy it, or save or print the page, and keep it somewhere safe.

  4. Activate

    Start ONAC Network Studio, paste the key into the activation window and click Activate. Your PC needs to be online for this step.

Requirements

System requirements

WindowsWindows 10 or 11, 64-bit
Processor & memoryAny modern dual-core CPU, 8 GB RAM recommended for large logs
Disk spaceAbout 1 GB, plus space for your recordings
Display1366 × 768 or larger
InterfacesONAC device (USB serial), PicoScope (with PicoSDK installed), Mongoose ISO3 (with its driver installed), or a CANable / candleLight USB-CAN adapter (no driver needed). None needed to work with recorded logs.
InternetTo activate, and at least once every 14 days
Need sending? The Standard edition is listen-only. ONAC Network Studio Pro adds Send Messages and is available to approved professionals.
Release notes

Version 2.6.4

November 2026. The installer is digitally signed and checks itself on start-up, so a damaged or modified copy won't run. Large logs (hundreds of MB) load, save and export in the background with a progress bar.

New in this version: reference signals - save a signal you've found (in Analysis Messages, Reverse Engineering or Live Reverse Engineering) and overlay it on other graphs while you look for related ones, with a readout of how closely they follow each other and at what time lag; references are read again from any log you load, decoded live in Live Reverse Engineering, and can be saved to a file for later sessions. The Messages plot can pop out into its own window, Reset Session sits beside the Light/Dark button, and graphs of long logs draw faster.

New in 2.6.2: a Messages view in Analysis lists every message on each channel and, for the one you pick, shows the fields found, how often each bit changes, a plot of any bits you select and every frame in hex, decimal, bit or ASCII; Compare Logs now compares every frame of two logs (changed, missing, extra and delayed frames) and shows both logs side by side at each difference; UDS diagnostic databases decode, and Automated Log Analysis works on diagnostic polling logs; the Analysis table and graphs can show interpolated, last-known or raw values; and loading several large logs uses far less memory and no longer freezes the app.

Capture and decode

  • Live Stream and Record from an ONAC device, PicoScope, Mongoose ISO3 or a CANable / candleLight USB-CAN adapter (plug in by USB, no driver to install). Always listen-only, so the adapter never transmits onto the vehicle.
  • Auto-detect baud rate, and clear bus diagnostics: if the bus can't be read cleanly, the app says whether it's the speed, the wiring or the ground connection.
  • PicoScope CAN, LIN and SENT with set-up guides and the voltage range set for you; LIN speed and SENT tick time detected automatically.
  • Live FlexRay with a PicoScope through a 10:1 probe on Bus Plus, every frame checked, with a set-up guide and safety notice. Slots that carry different messages in different cycles can be split into separate messages.
  • Record Live Values and save as CSV, MATLAB, MoTeC or MDF, with the real time of day on every value.
  • Load Database and Analysis: decode with DBC, LDF and FIBEX files (with or without PDUs), including multiplexed signals, with pop-out graphs you can group however you like.

Reverse engineering

  • Reverse Engineering: signal miner, Live analysis, Find a Specific Signal (matches your reference readings on your PC) and Automated Log Analysis, with results exported to DBC (CAN, CAN FD, SENT), LDF (LIN) and FIBEX (FlexRay).
  • Guided Test: step-by-step actions on the vehicle, and the app finds the signals that respond. Pick petrol/diesel, hybrid or EV and it chooses the right steps, including telematics and fleet steps (seatbelts, cruise control, reverse, wipers, boot) and EV and hybrid steps (charge flap, charging, regen, climate power, EV-only mode - low-voltage controls only).
  • Odometer, fuel, charge and range: Automated Log Analysis finds them in a recorded log by comparing them with vehicle speed. Optionally add the mileage, fuel or charge shown at the start and end of the log to pin the scaling exactly.
  • Find the VIN and other text, even when it's split across several frames, plus software versions, part numbers and other readable text on the bus.
  • Automated Log Analysis works out signals from how the vehicle behaves, on your PC. Choose the vehicle type for hybrid and EV battery signals; battery cell voltage and temperature arrays are recognised, and the VIN is looked for automatically.
  • Pro: Send Messages through a Mongoose ISO3 or CANable, and a Guided Test driving step.
Your licence

Common questions

How many PCs can I use?

Each licence key works on up to two PCs at once. To move it to a new PC, open Licence → Deactivate this PC on the old one first.

Does it work offline?

Yes. After activation the app only needs to reach our licence service occasionally, and keeps working for up to 14 days without a connection — handy in a workshop or at a test track.

How do I cancel?

Open Licence → Manage Subscription in the app to manage or cancel a monthly subscription. There's no minimum term.

Who handles payment?

Payments are processed by Stripe. We never see or store your card details.

Does the analysis need an AI account?

No. Automated Log Analysis, Find a Specific Signal and the rest of the app run on your PC at no extra cost, and your logs stay on your computer.

Lost your licence key?

Email contact@onactech.co.uk from the address you bought with and we'll look it up for you.

Something not working?

Email contact@onactech.co.uk with your licence key's last few characters and what you're seeing, and we'll help.